95期6场半全场|6场半全场中奖规则
Applications of Fiber Optics Sensors in Seismology
Simulation Analysis of Fiber Optic Magnetic Sensor
Enhancement of excited-state emission of InAs/GaAs quantum dots with larg...
Self-Powered SnS1-xSex Alloy/Silicon Heterojunction Photodetectors with H...
Mode and lasing characteristics for scissor-FP hybrid-cavity semiconducto...
14 mu m quantum cascade lasers based on diagonal transition and nonresona...
Exploring the Designs of p-Type Piezoelectric FinFETs Based on NEGF Trans...
Insulator-metal transition and ultrafast crystallization of Ga40Sb60/Sn15...
Atomic mechanism of strong interactions at the graphene/sapphire interface
Self-catalyzed growth of GaSb nanowires for high performance ultraviolet-...
官方微信
友情鏈接

A Resonant Z-Axis Aluminum Nitride Thin-Film Piezoelectric MEMS Accelerometer

2019-10-24

Authors: Yang, J; Zhang, M; He, YR; Su, Y; Han, GW; Si, CW; Ning, J; Yang, FH; Wang, XD

MICROMACHINES

Volume: 10 Issue: 9 Published: SEP 2019 Language: English Document type: Article

DOI: 10.3390/mi10090589

Abstract:

In this paper, we report a novel aluminum nitride (AlN) thin-film piezoelectric resonant accelerometer. Different from the ordinary MEMS(micro-electro-mechanical systems) resonant accelerometers, the entire structure of the accelerometer, including the mass and the springs,is excited to resonate in-plane, and the resonance frequency is sensitive to the out-plane acceleration. The structure is centrosymmetrical with serpentine electrodes laid on supporting beams for driving and sensing. The stiffness of the supporting beams changes when an out-plane inertial force is applied on the structure. Therefore, the resonance frequency of the accelerometer will also change under the inertial force. The working principle is analyzed and the properties are simulated in the paper. The proposed AlN accelerometer is fabricated by the MEMS technology, and the structure is released by an ICP isotropic etching. The resonance frequency is 24.66 kHz at a static state. The quality factor is 1868. The relative sensitivity of this accelerometer, defined as the shift in the resonance frequency per gravity unit (1g = 9.8 m/s(2)) is 346 ppm/g. The linearity of the accelerometer is 0.9988. The temperature coefficient of frequency (TCF) of this accelerometer is -2.628 Hz/degrees C (i.e., -106 ppm/degrees C), tested from -40 degrees C to 85 degrees C.

Full Text: https://www.mdpi.com/2072-666X/10/9/589



關于我們
下載視頻觀看
聯系方式
通信地址

北京市海淀區清華東路甲35號 北京912信箱 (100083)

電話

010-82304210/010-82305052(傳真)

E-mail

[email protected]

交通地圖
版權所有 ? 中國科學院半導體研究所

備案號:京ICP備05085259號 京公網安備110402500052 中國科學院半導體所聲明

95期6场半全场 浙江飞鱼 50万闲钱如何理财 合肥沐足按摩论坛 篮球比分网官网 黑龙江十一选五基本 网球比分直播雷速 零基础学麻将 山西泳坛夺金 谷原希美 福彩3d开奖结果查询 混合过关 微信打麻将开挂软件 3d试机号后分析预测 河南快3 日本av女优性爱视频 手机麻将app哪个好